Three-phase resistor loads
Advantages
- Eight three-phase fixed levels for testing power supplies and thermal behavior with active power
- Switching the individual stages on and off under load using a rotary switch
- Display via digital ammeters (96 x 48 mm) truly effective in the control panel
- Connections on 4 mm safety laboratory jacks
Technical data*
Resistance | Currents | Power | Rated voltage | Total power | Degree of protection |
3 x 2300 R | 3 x 0.1 A | 69 W | 3 x 400 V L/L or 3 x 230 V L/L 50/60 Hz |
11.385 kW | IP20 |
---|---|---|---|---|---|
3 x 1150 R | 3 x 0.2 A | 138 W | |||
3 x 575 R | 3 x 0.4 A | 276 W | |||
3 x 288 R | 3 x 0.8 A | 552 W | |||
3 x 230 R | 3 x 1 A | 690 W | 3 x 115 R | 3 x 2 A | 1380 W | 3 x 57.5 R | 3 x 4 A | 2760 W | 3 x 28.8 R | 3 x 8 A | 5520 W |
All data and configurations can be found in our product datasheet.