Active Current Transformer Series WKO

Closed-loop current transformers Description Closed-loop current transformers The WKO current sensors work according to the proven compensation principle and are suitable for measuring direct, alternating and mixed currents. The primary current flow generates a magnetic flux, which is compensated by an internal secondary coil.The current evaluation is realized with an electronic circuit and a Hall sensor. The secondary compensation current is an exact reflection of the primary current to be measured. Unique Selling Point Measurement of direct, alternating and mixed currents Very high precision and short response time Broad frequency spectrum and low-temperature drift Very good linearity and overcurrent resistance No additional losses in the measuring circuit (DC to 150 kHz) Current output for lengthy transmission lines High-quality UL-listed insulating materials (e.g. UL94-V0) Advantages (mechanical) Robust housing designs (for horizontal/vertical mounting) Variable connections, e.g. clamps, plugs, flat-cable plugs or cables Wide range of housings with various push-through openings Push-through openings Typical applications Industry, Renewable energy, Railway engineering, Energy, automation and building technology ELECTRICAL DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Primary RMS nominal current IPN [A] 25 50 100 300 500 1000 Measuring range IP [A] 0…±35 0…±70 0…±150 0…±500 0…±1000 0…±1500 Supply UC [V] ±12 …15 ±12 …15 ±12 …15 ±12 …15 ±12 …24 ±12 …24 Measuring accuracy XG@Ipn [-20…70°C] from IPN [%] > ±0,9 > ±1 > ±1 > ±1 > ±1 > ±1 Translation KN 1000 1000 1000 2000 5000 5000 Secondary RMS Nominal current ISN [mA] 25 50 100 150 100 200 Secondary winding Resistive sand RS@70°C [Ω] 16 43 24 30 72 48 No load current [mA] 36+IS 11+IS 36+IS 36+IS 36+IS 24+IS ACCURACY AND DYNAMIC DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Linearity error e [%] < ±0,1 < ±0,1 < ±0,1 < ±0,1 < ±0,1 < ±0,1 Offset error@25°C IO [mA] > 0,3 > 0,3 > 0,4 > 0,2 > 0,2 > 0,3 Offset Drift -25°C…+70°C IOT [mA] > 0,5 > 0,5 > 1 > 0,5 > 0,5 > 0,5 Response time tra[μs] > 0,5 > 0,5 > 0,5 > 0,5 > 0,5 > 0,5 Response time 10%-90% ta [μs] > 1 > 1 > 1 > 1 > 1 > 1 dl/dt ta [A/μs] > 50 > 50 > 100 > 100 > 100 > 100 Bandwidth -1 dB [kHz] DC…150 DC…200 DC…100 DC…100 DC…100 DC…100 ISOLATION DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Creepage distance dCp [mm] 4 8 10 10 10 15 Air section dCi[mm] 3 7 9 9 9 12 Creepage Strength [CTI] 600 600 600 600 600 600 AC-Insulation test 50/60Hz 1min Ud [kV] 3,8 3,8 3,8 3,8 6 6 Pulse voltage test 1,2/50μs Ui[kV] 6 6 6 6 12,5 14,5 Mass[kg] [kg] 0,08 0,022 0,125 0,125 0,240 0,450 Dimensions in mm Type Pin connection/ 4-pin h [mm] b [mm] b1/b2 [mm] t [mm] DL [mm] p/s [mm] a/a1 [mm] c1/c2 [mm] f [mm] e [mm] l [mm] WKO 25 A; -U; +U 39 39 – 26 10 – 2 x 10/6,5 25/6,5 M3 6,0 x 4,0 9 WKO 50 A; -U; +U Please find in the drawing WKO 100 A; -U; +U 55 – 55/68 26 20,2 45/45 – 13,0/– 4,3 6,0×4,0 12 WKO 300 A; -U; +U 55 – 55/68 26 20,2 45/45 – 13,0/– 4,3 6,0×4,0 12 WKO 500 A; -U; +U 70 – 70/89 33 31,0 57/57 – 15,2/– 4,3 6,0×4,3 12 WKO 1000 A; -U; +U 95 – 94/110 44 40,0 78/78 – 18,0/– 5,3 8,0×5,3 12 Data sheet All data and configurations can be found in our product data sheet. Download data sheet Certifications