AC MAGNET REOVIB WI 211

AC magnet with configurable voltage/frequency options ADVANTAGES Maximum power 250 VA Configurable voltage/frequency options increases flexibility Quick change of the connection voltage by using the appropriate Low Profile TYPICAL APPLICATIONS Packaging industry and weighing sector for feeding and sorting processesAutomation process and assembly equipment which utilises electromagnetic drives. TECHNICAL SPECIFICATION Types Maximum rated air gap [mm] [mm] Power at 3000 1/min [VA] Rated current = thermal rated current at 230V [A] Peak tensile force at nominal air gap [N] Weight Magnet [kg] Weight Armature [kg] 6000 1/min [VA] REOVIB WI 211/7 1 175 0,75 40 1,15 0,165 REOVIB WI 211/9 1 210 0,9 105 1,96 0,33 REOVIB WI 211/10 1 250 1,1 210 2,1 0,34 *Suitable REOVIB control units: REOVIB SMART, REOVIB RTS, REOVIB MTS, REOVIB MFS *Typical applications: Packaging and weighing industry for feeding and sorting processes, automation processes when using drives with vibrating solenoids DIMENSIONS IN MM Types a [mm] b [mm] c [mm] d e f f1 f2 f3 f4 g h [mm] i k p r s [mm] ⌀t REOVIB WI 211/7 78 47 54 60 3 77 74 17 10 22 54 21 20 31 20 6,5 37 6,5 REOVIB WI 211/9 90 56 66 83 3 91 88 19 11 24 66 32,5 22 31 44 8,1 44 8 REOVIB WI 211/10 100 68 66 – – – 61,5 12 9 48 66 38 17,5 31 30 M6 – – Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications

Programmable Phase Angle Controller REOVIB MTS 620

IP 20, single-channel control DESCRIPTION The control unit REOVIB MTS 620 is a phase-angle control for adjusting the feed speed of vibratory conveyors. All parameters can be entered via the LED display. User-specific settings can be saved and recalled. The device is available in protection class IP20. The REOVIB MTS series includes single, dual, and triple-channel control units for vibratory feeder drives. These are phase-angle controls. Consequently, the vibration frequency of the conveying devices can be equal to or twice as high as the mains frequency of the input voltage (depending on the type, other frequencies are also possible). Plug connections for all inputs and outputs enable quick connection and facilitate the combination of multiple devices with each other or with external controls. The devices use digital technology and are operated via a LED or LCD display and buttons All settings can be made without the housing having to be opened. The REOVIB MTS 620 devices are available in IP20 version. ADVANTAGES Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude TECHNICAL SPECIFICATION Mains input 230V, 400 V, 480 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 210 V, 360 V, 430 V Output current 25 A Number of outputs 1 Max. Output current from all outputs – Vibration frequency 50 Hz (25 Hz, 33,3 Hz, 50 Hz, 100 Hz) 60 Hz (30 Hz, 40 Hz, 60 Hz, 120 Hz) Setpoint value LED-Display, 0 … 10 V, 0 (4) … 20 mA Status signal Relay changer 250 V, 1 A Ext. Enable 24 V DC, Switch Sensor supply 24 V DC (optional) Setting Umin/ Umax Display Soft start adjustable 0…60 Sec. With fill level/overflow control PNP, 24 V DC (optional) Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable timer function – Sensor time out monitor – Conformity CE, RoHS Protection class IP20 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications

Programmable Phase Angle Controller REOVIB MTS 443

IP54, three-channel control DESCRIPTION The REOVIB MTS series includes single-channel, two-channel and three-channel control units for vibratory conveyor drives. These are phase-angle control systems. The vibration frequency of the conveyor can be the same as or twice the frequency of the input voltage. (Other frequencies are possible depending on the type). Plug and socket connections for all inputs and outputs make rapid installation possible and facilitate the combination of several devices with each other or with external control systems The devices use digital technology and are operated via a LED or LCD display and buttons All settings can be made without the housing having to be opened. REOVIB MTS 441 control devices have a target value setting for conveying speed. The REOVIB MTS 442 has two power outputs and the REOVIB MTS 443 has 3 power outputs, that can be linked according to the the application requirements (e.g. bowl and linear conveyors). Also Various sensor and valve logic can be programmed. All parameters of REOVIB MTS 441, 442 und 443 can be input via a display integrated into the faceplate. The devices can be used to link additional devices from the REOVIB MTS series. Application-specific settings can be stored and retrieved when required. The devices of REOVIB MTS 441 and 620 are available in protection class IP20.Additionally the REOVIB MTS 441 is just as the REOVIB MTS 442and 443 available in a standalone IP54 housing with various connection options: Input cable/output socket Complete cable connection solution for mains, output and control connections with LCD displayThe full-text display in various languages makes programming and adjustment easy and intuitive. Important status indications and settings can easily be input and retrieved. ADVANTAGES Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude TECHNICAL SPECIFICATION REOVIB MTS 443 Mains input 110/ 230 V autom. recognition Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current per output max. 6A Number of outputs 3 Max. Output current from all outputs 15 A Vibration frequency 50/ 100 Hz (60/120Hz) Setpoint input Display Status signal 24 V DC Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start adjustable 0…5 sec. With fill level / overflow control Per output PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out monitor ✓ Conformity CE, RoHS Protection class IP54 TECHNICAL SPECIFICATION REOVIB MTS 443 LCD Mains input 110/ 230 V autom. recognition Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current per output max. 6A Number of outputs 3 Max. Output current from all outputs 15 A Vibration frequency 50/ 100 Hz (60/120Hz) Setpoint input Display Status signal 24 V DC Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start adjustable 0…5 sec. With fill level / overflow control Per output PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out monitor ✓ Conformity CE, RoHS Protection class IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications

Programmable Phase Angle Controller REOVIB MTS 442

IP 20, single-channel control DESCRIPTION The REOVIB MTS series includes single-channel, two-channel and three-channel control units for vibratory conveyor drives. These are phase-angle control systems. The vibration frequency of the conveyor can be the same as or twice the frequency of the input voltage. (Other frequencies are possible depending on the type). Plug and socket connections for all inputs and outputs make rapid installation possible and facilitate the combination of several devices with each other or with external control systems. The devices use digital technology and are operated via a LED or LCD display and buttons. All settings can be made without the housing having to be opened. REOVIB MTS 441 control devices have a target value setting for conveying speed. The REOVIB MTS 442 has two power outputs and the REOVIB MTS 443 has 3 power outputs, that can be linked according to the the application requirements (e.g. bowl and linear conveyors). Also Various sensor and valve logic can be programmed. All parameters of REOVIB MTS 441, 442 und 443 can be input via a display integrated into the faceplate. The devices can be used to link additional devices from the REOVIB MTS series. Application-specific settings can be stored and retrieved when required. The devices of REOVIB MTS 441 and 620 are available in protection class IP20. Additionally the REOVIB MTS 441 is just as the REOVIB MTS 442 and 443 available in a standalone IP54 housing with various connection options: Input cable/output socket Complete cable connection solution for mains, output and control connections ADVANTAGES Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude TECHNICAL SPECIFICATION Mains input 110/ 230 V autom. recognition Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current per output max. 6A Number of outputs 2 Max. Output current from all outputs 15 A Vibration frequency 50/ 100 Hz (60/120 Hz) Setpoint specification Display Status signal 24 V DC Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start Adjustable 0…5 Sec. Full level control / congestion control each output PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out control ✓ Conformity CE, RoHS Protection class IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung

Programmable Phase Angle Controller REOVIB MTS 441

IP54 or IP20 DESCRIPTION The REOVIB MTS series includes single-channel, two-channel and three-channel control units for vibratory conveyor drives. These are phase-angle control systems. The vibration frequency of the conveyor can be the same as or twice the frequency of the input voltage. (Other frequencies are possible depending on the type). Plug and socket connections for all inputs and outputs make rapid installation possible and facilitate the combination of several devices with each other or with external control systems. The devices use digital technology and are operated via a LED or LCD display and buttons. All settings can be made without the housing having to be opened. The REOVIB MTS 441 control units have a setpoint adjustment option for the conveying speed. All parameters can be entered via the display integrated in the front panel. The MTS 441 can be linked to other devices from the REOVIB MTS series. User-specific settings can be saved and recalled. The REOVIB MTS 441 is available in IP20 and IP54 versions, as well as in various connection variants: Input cable/output socket Complete cable connection solution for mains, output and control connections ADVANTAGES Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude TECHNICAL SPECIFICATION Mains input 110/ 230 V autom. recognition Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current max. 6 A, max. 10 A (Option) Number of outputs 1 Max. Output current from all outputs – Vibration frequency 50 … 100 Hz (60/120 Hz) Setpoint value Display, P0ti, 0 … 10 V, 0 (4) … 20 mA Status signal 24 V DC Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start Adjustable 0…5 Sec. Fill level/ overflow control PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out control ✓ Conformity CE, RoHS Protection class IP20/ IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung

Phase angle control REOVIB RTS SYSTEM

IP00, switch cabinet mounting DESCRIPTION Basic module RTS SYSTEM In open design for mounting on a DIN rail with an output channel of max. 6 A with fill level control/level switch and mains voltage compensation. The basic module has a power supply for expansion modules. This means that additional output modules can be added up to a total current of 10 A. RTS SYSTEM extension module In open design for mounting on a DIN rail. The extension module has an output channel max. 6 A with level control/level switch and mains voltage compensation and can be installed together with the basic module and several extension modules. REOVIB RTS SINGLE In open design for mounting on a DIN rail with an output channel of max. 6 A, level control/level switch and mains voltage compensation. ADVANTAGES Cost-effective phase control units with protection class IP00 for control cabinet installation Can be used as a standalone device or in modular design for control of a complete feed system Output current up to 6A Versions available with fill level/overflow control Mains voltage compensation with constant amplitude Adjustable soft start ramp time TYPICAL APPLICATIONS Conveyor & assembly automation, conveyor technology, sieving technology TECHNICAL SPECIFICATION RTS Single RTS basic module RTS extension module Mains input 110/ 230V switchable 110/ 230V switchable via RTS basic module Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz via RTS basic module Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch 24 V DC, Switch Umin/ Umax internal potentiometers internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. adjustable 0.2…5 sec. Max. Output current from all outputs – 15 A – Mains voltage compensation ✓ ✓ ✓ Fill level control/ congestion control ✓ ✓ ✓ Conformity CE, RoHS CE, RoHS CE, RoHS Protection class IP00 IP00 IP00 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung

Phase Angle Controller REOVIB RTS RS6/539

IP54 design for mounting directly on the vibrating machine, single output DESCRIPTION The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant oscillation amplitude in the event of mains voltage fluctuations, potentiometers for setting the Umin / Umax and the soft start time as well as a level control/back-up circuit. (Devices with level control/back-up circuit contain a back-up relay for linking with other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket Complete cable connection solution for mains, output and control connections(For REOVIB RTS RS6/539-559). ADVANTAGES Versions available with fill level/overflow control Inexpensive phase angle controls with extended functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6A Mains voltage compensation with constant amplitude Adjustable soft start ramp time TYPICAL APPLICATIONS Conveyor & assembly automation, conveyor technology, sieving technology TECHNICAL SPECIFICATION RTS R6/539 RTS RS6/539-559 Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V 20 … 100V/ 40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120 Hz) 50 … 100 Hz(60/120 Hz) Setpoint specification Potentiometer, 0 … 10 V, 0 … 20 mA Potentiometer, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch Umin/ Umax internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung

Phase Angle Controller REOVIB RTS R6/539

IP54 design for mounting directly on the vibrating machine, single output DESCRIPTION The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant amplitude in the event of mains voltage fluctuations, potentiometers for setting Umin / Umax and the soft start time. (Devices with fill level control / back-up circuit include a back-up relay for linking to other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket ADVANTAGES Inexpensive phase angle controls with extended functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6A Versions with level control / accumulation circuit available (REOVIB RTS RS6/539-559) Mains voltage compensation with constant amplitude Adjustable soft start ramp time TYPICAL APPLICATIONS Conveyor & assembly automation, conveyor technology, sieving technology TECHNICAL SPECIFICATION Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch Umin/ Umax setting Internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung />

REOVIB SMART System phase-angle gates

IP00, for assembly on a DIN rail DESCRIPTION Basic module REOVIB SMART SYSTEM In open design for assembly on a DIN rail with an output channel of max. 6A with fill level/overflow control. The basic module has a supply for expansion modules, so further output modules up to a total current of 10A can be connected. REOVIB SMART SYSTEM extension module REOVIB SMART SYSTEM extension module in open design for DIN rail mounting. An extensionmodule has an output channel max. 6A with fill level/overflow control and can be set uptogether with the basic module and several extension modules. REOVIB SMART SINGLE In open design for mounting on a DIN rail with an output channel of max. 6 A. ADVANTAGES Cost-effective phase-angle control systems with vital functionality Can be used as a standalone device or in modular design for control of a complete feed system Output current up to 6A DIN rail mounting Versions available with fill level/overflow control TYPICAL APPLICATIONS Weighing systems, multiple-head weighing wagon, conveyor & assembly automation, sorting systems TECHNICAL SPECIFICATION Types SMART Single SMART basic module SMART extension module Mains input 110/ 230 V switchable 110/ 230 V switchable via SMART basic module Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz via SMART basic module Output voltage 20 … 100V/ 40…210 V 20 … 100V/ 40…210 V 20 … 100V/ 40…210 V Output current max. 6 A max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120 Hz) 50 … 100 Hz(60/120 Hz) 50 … 100 Hz(60/120 Hz) Setpoint specification Potentiometer, 0 … 10 V, 0 (4) … 20 mA Potentiometer, 0 … 10 V, 0 (4) … 20 mA Potentiometer, 0 … 10 V, 0 (4) … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch 24 V DC, Switch Umin/ Umax internal potentiometers internal potentiometers internal potentiometers Soft start permanently defined permanently defined permanently defined Max. output current of all outputs – 10 A – Level control/ accumulation control – ✓ ✓ Conformity CE, RoHS CE, RoHS CE, RoHS Protection class IP00 IP00 IP00 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt

AC MAGNET REOVIB WI 111

IP 00, for DIN rail mounting DESCRIPTION Standard series, fully encapsulated, maximum power of 350 VA at 3000 1/min or 6000 1/min Mounting by means of standard round holes, base plate or slotted holes Cable exit downwards or sideways ADVANTAGES Optimal size/performance ratio Good adjustability Safe mounting by means of solid base plate/mountings through the core Compact and robust structure TYPICAL APPLICATIONS Packaging industry and weighing sector for feeding and sorting processesAutomation process and assembly equipment which utilises electromagnetic drives. TECHNICAL SPECIFICATION Types Maximum rated air gap [mm] [mm] Power at 3000 1/min [VA] Rated current = thermal rated current at 230 V [N] Peak tensile force at nominal air gap [N] Weight [kg] 6000 1/min [VA] Magnet Armature REOVIB WI 111/3 2 15 0,065 5 0,135 0,025 REOVIB WI 111/5 1 60 0,26 38 0,405 0,085 REOVIB WI 111/6 2,5 70 0,3 24 0,58 0,11 REOVIB WI 111/7 3 140 0,6 45 1,15 0,165 REOVIB WI 111/9 3 350 1,5 150 1,98 0,33 Technical Dimensions Types a [mm] b [mm] c [mm] d e f1 f2 f3 g h [mm] i k l [mm] l1 m ⌀n ⌀o p ⌀r s [mm] ⌀t REVIB WI 111/3 44,4 26,4 30 32 2 42 9 5 30 12 10 4,2 22 20 22 4,2 4,4 – 4,4 20 3,6 REVIB WI 111/5 61,5 31,5 45 50 3 63 14 7,5 45 16 15 3 43 35 36 4,2 4,4 15 5,1 28 5,1 REVIB WI 111/6 64 42 45 50 3 63 14 7,5 45 20,5 15 – 43 35 36 4,2 4,4 15 5,1 28 5,1 REVIB WI 111/7 78 47 54 60 3 77 17 10 54 21 20 4,5 45 40 45 7 5,5 20 6,5 37 6,5 REVIB WI 111/9 90 56 66 83 3 88 19 11 66 32,5 22 – 66 50 66 7 6,4 44 8,1 44 8,1 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications