Active Current Transformer Series WKO-2C

Double core technology closed-loop current transformers

DESCRIPTION

REO has developed a new generation of closed-loop (C/L) current transducers which guarantees increased current measurement accuracy better than 0.3% in the whole frequency range: DC to 150 kHz. The new current transducer type WKO-2C is a completely new development utilizing REO’s double-core technology magnetic design. The unit uses the latest Hall effect elements with an extended frequency response of up to 150 kHz and an accurate phase response.

Completely redesigned electronics ensure that the new C/L current transducer has better drift compensation and an extended temperature range from -40°C to 85°C.

Modular mounting plates providing universal mounting options

All REO current transformers in the WKO-2C series work according to the proven compensation principle and are suitable for measuring direct and alternating currents.

According to

  • EN 50178:1997, UL 94-V0
  • EN50121, EN55011
  • IEC61869-1, IEC61869-8, IEC61010-1
  • According to: EN 50178:1997, UL 94-V0

ADVANTAGES

  • High current measurement accuracy of 0.3%
  • Modular mounting plates providing universal mounting options
  • Lower sensitivity to external magnetic fields
  • Bidirectional and isolated current measurement up to ±750A current output
  • Modular mounting plates
  • REO double core technology
  • All materials manufactured using UL-listed materials

Typical applications

  • Power electronics: AC-DC motor control, inverter technology, drive control
  • Railway technology: drive control
  • Renewable energy: control and monitoring of wind turbines
  • Accuracy: better than 0.3%
  • Ambient temperature: -40 ° C… + 85 ° C
  • Storage temperature: -40 ° C… + 90 ° C
  • Primary rated current: 300 – 2000 A
  • Measurement range: 0… 4000 A
  • Frequency range: 150000 Hz
Type Primary RMS Nominalcurrent
IPN [A]
Measurement range
IP[A]
Feed-in
UC [V]
Measurement accuracy
XG@Ipn
[-20…70°C]
von IPN [%]
Ratio
KN
Secondary RMS
nominal current
ISN [mA]
Secondary winding
Resistor
Rs@85°C [Ω]
No-load current
[mA]
WKO-2C-300 300 0…±2000 ±11,4…25,2 >±0,3 2000 150 13 26+IS
WKO-2C-500 500 0…±1000 ±11,4…25,2 >±0,3 5000 100 76 26+IS
WKO-2C-1000 1000 0…±2700 ±14,25…25,2 >±0,3 5000 200 42 26+IS
WKO-2C-2000 2000 0…±4000 ±14,25…25,2 >±0,3 5000 400 26 26+IS
Type Linearity error
e [%]
Offset error@25°CIO [mA] Offset Drift-25°C…+70°CIOT [mA] Response time
tRA [μs]
Response time10%-90%ta [μs] dl/dt
ta [A/μs]
Bandwidth
-1 dB [kHz]
WKO-2C-300 < ±0,1 ±0,5 <25 0,2 0,4 400 150
WKO-2C-500 < ±0,1 ±0,5 <25 0,2 0,4 400 150
WKO-2C-1000 < ±0,1 ±0,5 <25 0,2 0,4 400 150
WKO-2C-2000 < ±0,1 ±0,5 <25 0,2 0,4 1000 150
Type Creepage distance
dCp [mm]
Air sectiondCi [mm] Creep distance
[CTI]
AC insulation test
50/60Hz 1min Ud [kV]
Pulse voltage test
1,2/50μs Ui [kV]
Mass
[kg]
[kg]
WKO-2C-300 14 13 600 6 12,5 0,340
WKO-2C-500 14 13 600 6 12,5 0,260
WKO-2C-1000 20 18 600 6 12,5 0,700
WKO-2C-2000 35 30 600 6 12,5 1,600
Type b1
[mm]
b2
[mm]
t
[mm]
s
[mm]
h
[mm]
D Ø
[mm]
D1/D2
[mm]
Ø f
[mm]
Ø e
[mm]
WKO-2C-300 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3
WKO-2C-500 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3
WKO-2C-1000 78 94 42 78 94 38,5 13,5/40,5 5,3 5,3
WKO-2C-2000 102 135 52 102 135 57,5 20,5/60,5 6,5 6,5