Gesamtkatalog

Laden Sie sich unseren umfangreichen Katalog herunter und entdecken Sie auch viele weitere Produkte von REO.

Test choke NPT 892

Single phase DC test choke

DESCRIPTION

Switches must pass many different tests during the approval phase. Some of these tests involve the switching behaviour under different load conditions, the switch is tested on nominal load, overload and at many cos. Additionally, the switch will be checked on switch on and switch off procedures. The parameters must be every time the same during these tests.

In the past, air chokes were used as inductive loads, since these do not saturate. Air chokes are larger and have a stronger leakage field than comparable core chokes with corresponding magnetic energy.

ADVANTAGES

  • Adapted linearity, no saturation in the workspace
  • Several taps, just a few chokes instead of many are needed
  • Adjusted winding resistance, thereby reducing resistive loads
  • Designed for continuous load and short-term exposure
  • Optimizing weight and dimensions, lower costs
  • High voltage, standard up to 1000V
  • Insulation class: F at 40° C
  • Climatic category: 25/085/21 DIN IEC 68 Part 1
  • Max.
    winding temperature: 140° C
  • Protection rating: IP 00
  • Nominal Voltage: 24 V
  • Rated current: 0,2 – 4 A
  • Inductance: 160 – 125000 mH
Type Nominal voltage [V] Nominal current [A] Inductance [mH] DC resistance [mΩ] Power loss [W]
NPT 892/0,2 24 50/60 Hz 0,2 125.000 197,3 20
NPT 892/2 24 50/60 Hz 2 1.200 2,855
NPT 892/4 24 50/60 Hz 4 160 2,8 64
Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] øD1 [mm] A1 [mm] Copper [kg] Weight [kg] [kg]
NPT 892/0,2 200 148 261 124 120 10×18 6,2 24 1 2
NPT 892/2 240 168 375 144 140 10×18 18 44 3 10
NPT 892/4 280 173 417 176 143 13×20 4,4 38 11 38

Passend zu diesem Produkt

EMV-Filter

Widerstände

Stromwandler