Gesamtkatalog

Laden Sie sich unseren umfangreichen Katalog herunter und entdecken Sie auch viele weitere Produkte von REO.

Test Choke RPD 9039

Three-phase load choke

DESCRIPTION

Drive inverters or output filters must be tested at rated current by using typical motor generators. Due to the high costs, the specimens can be loaded alternatively with chokes which have sufficient linearity and do not exceed the temperature limit at higher frequencies.

ADVANTAGES

  • Small dimensions
  • Cost-effective solution
  • Cooling: AN
  • Insulation class F
  • Climatic category: 25/085/21 DIN IEC 68 Part 1
  • Max.
    winding temperature: 140 °C
  • Protection rating: IP 00
  • Rated voltage : 400 V
  • Rated current : 0,6 – 75 A
  • Inductance : 3,15 – 254 mH
Type Rated voltage [V] Rated current [A] Inductance [mH] DC resistance [mΩ] Power loss [W]
RPD 9039/0,6 3 x 400 0,6 254 6009,2 20
RPD 9039/7,0 3 x 400 7 31,4 221,7 70
RPD 9039/32,0 3 x 400 32 8,550 34,3 230
RPD 9039/75,0 3 x 400 75 3,150 12,6 430
Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] øD1 [mm] A1 [mm] Copper [kg] Weight [kg] [kg]
RPD 9039/0,6 125 91 85 100 52 5 x 8 9 33,1 1 2
RPD 9039/7,0 190 123 157 170 79 8 x 12 9 34,5 3 10
RPD 9039/32,0 300 168 264 224 120 10 x 18 9 34,7 11 38
RPD 9039/75,0 360 182 313 264 142 10 x 18 9 35,7 18 58

Passend zu diesem Produkt

EMV-Filter

Widerstände

Stromwandler