Three-phase line filters (4 lines, single stage) (3A – 150A)
DESCRIPTION
NEW SERIES!
The new series not only scores points for its faster delivery time, but also for its resource conservation and increased efficiency.
Recommended filter for interference suppression according to EN 55011, Class A and EN 61800-3, Category C2.
By using a REO three-phase line filter CNW 105 the noise level is reduced below the prescribed maximum value.
REO line filters are suitable for individual and collective suppression.
For collective suppression: As long as the rated current for each phase remains below the permissible extent, multiple devices can be suppressed.
ADVANTAGES
- Small dimensions
- quick connection
- low-temperature rise
- touch-proof terminals
- good damping performance at
a low leakage current
TYPICAL APPLICATIONS
Power supply units for data systems engineering, telecommunications, medical equipment and industrial applications
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Part 1 25/085/21
Type | Rated voltage [V] | Rated current [A] | Leakage current [A][mA] | Cx [μF] |
Cy nF] |
L [mH] |
R [MOhm] |
Frequency[Hz] |
N CNW 105/3 | 3×500 | 4×3 | <1 | 0,5 | 30 | 4,0 | 1,12 | 50/60 |
N CNW 105/6 | 3×500 | 4×6 | <1 | 0,5 | 30 | 2,4 | 1,12 | 50/60 |
N CNW 105/10 | 3×500 | 4×10 | <1 | 0,5 | 30 | 1,0 | 1,12 | 50/60 |
N CNW 105/16 | 3×500 | 4×16 | <1 | 1 | 43 | 1,6 | 1,12 | 50/60 |
N CNW 105/25 | 3×500 | 4×25 | <1 | 1 | 43 | 1,4 | 1,12 | 50/60 |
N CNW 105/36 | 3×500 | 4×36 | <1 | 2,2 | 44 | 1,2 | 1,12 | 50/60 |
N CNW 105/50 | 3×500 | 4×50 | <1 | 2,2 | 44 | 0,75 | 1,12 | 50/60 |
N CNW 105/80 | 3×500 | 4×80 | <3,5 | 3,3 | 111 | 0,5 | 1,12 | 50/60 |
N CNW 101/120 | 3×500 | 4×120 | <3,5 | 3,3 | 111 | 0,36 | 1,12 | 50/60 |
CNW 105/150 | 3×500 | 4×150 | <3,5 | 3,3 | 111 | 0,36 | 1,12 | 50/60 |
Type | Housing | Connection | PE-Connection | B1[mm] | B2[mm] | B2[mm] | D[mm] | H[mm] | L1[mm] | L2[mm] | L3[mm] |
CNW 105/3 | A | Flat plug 6,3 mm | AMP flat plug | 53 | – | – | 5,3 | 40 | 110 | 100 | 90 |
CNW 105/6 | A | Flat plug 6,3 mm | AMP flat plug | 53 | – | – | 5,3 | 40 | 110 | 100 | 90 |
CNW 105/10 | A | Flat plug 6,3 mm | AMP flat plug | 53 | – | – | 5,3 | 40 | 110 | 100 | 90 |
CNW 105/16 | B | Clamps 4mm² | Earthing bolt (M6) | 98 | 80 | 70 | 5,0 | 70 | 177 | 150 | 90 |
CNW 105/25 | B | Clamps 6mm² | Earthing bolt (M6) | 98 | 80 | 70 | 5,0 | 70 | 179 | 150 | 90 |
CNW 105/36 | B | Clamps10mm² | Earthing bolt (M6) | 148 | 135 | 120 | 7,0 | 70 | 269 | 240 | 160 |
CNW 105/50 | B | Clamps 25mm² | Earthing bolt (M6) | 148 | 135 | 120 | 7,0 | 70 | 278 | 240 | 160 |
CNW 105/80 | B | Clamps 25mm² | Earthing bolt (M10) | 168 | 155 | 140 | 7,0 | 90 | 303 | 240 | 160 |
CNW 105/120 | B | Clamps 50mm² | Earthing bolt (M12) | 168 | 155 | 140 | 7,0 | 90 | 331 | 240 | 160 |
CNW 105/150 | B | Clamps 50mm² | Earthing bolt (M12) | 168 | 155 | 140 | 7,0 | 90 | 331 | 240 | 160 |