IP54 design for mounting directly on the vibrating machine, single output
DESCRIPTION
The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant amplitude in the event of mains voltage fluctuations, potentiometers for setting Umin / Umax and the soft start time. (Devices with fill level control / back-up circuit include a back-up relay for linking to other control devices).
The control units are available in different versions:
- Input cable/output cable
- Input cable/output socket
ADVANTAGES
- Inexpensive phase angle controls with extended functionalities
- IP54 design for mounting directly on the vibrating machine
- Output current up to 6A
- Versions with level control / accumulation circuit available (REOVIB RTS RS6/539-559)
- Mains voltage compensation with constant amplitude
- Adjustable soft start ramp time
TYPICAL APPLICATIONS
Conveyor & assembly automation, conveyor technology, sieving technology
Mains input | 110/ 230 V switchable | 110/ 230 V switchable |
Mains frequency | 50 / 60 Hz +/- 3 Hz | 50 / 60 Hz +/- 3 Hz |
Output voltage | 20 … 100V/40…210 V | 20 … 100V/40…210 V |
Output current | max. 6 A |
max. 6 A |
Vibration frequency | 50 … 100 Hz(60/120Hz) | 50 … 100 Hz(60/120Hz) |
Setpoint specification | P0ti, 0 … 10 V, 0 … 20 mA | P0ti, 0 … 10 V, 0 … 20 mA |
Ext. Enable | 24 V DC, Switch | 24 V DC, Switch |
Umin/ Umax setting | Internal potentiometers | internal potentiometers |
Soft start | adjustable 0.2…5 sec. | adjustable 0.2…5 sec. |
Status relay | optional | ✓ |
Mains voltage compensation | ✓ | ✓ |
Fill level control/ congestion control | – | ✓ |
Conformity | CE, RoHS | CE, RoHS |
Protection class | IP54 | IP54 |
*For IP54
Download our extensive catalog and discover many other REO products.