Inductive Load Unit REOCHOKE 300

The three-phase choke load consists of three iron core chokes, each with three taps, and is used for testing converters and switching power supplies.
Inductive Load Unit REOCHOKE 300/69

Infinitely adjustable three-phase choke load consisting of a three-phase variable autotransformer and a three-phase iron core choke connected on the secondary side, for testing converters and power supplies with reactive current.
Inductive Load Unit REOCHOKE 100 Mobile

For testing frequency converters with inductive load.
Inductive Load Unit NPT LD

These Chokes are used for continuous testing of inverters.
Inductive Load Unit Single-phase load inductor NPT

These Chokes are used as load chokes for testing single and multi-phase traction inverters as well as individual circuit breakers.
Inductive Load Unit CNW MD

REO also offers all Chokes in a liquid-cooled design.
REOLOAD 302 Ohmic Load Units

Eight three-phase fixed levels for testing power supplies and thermal behavior with active power.
Ohmic load unit REOLOAD 301

Ten fixed levels per plug-in unit for testing contacts, converters and switched-mode power supplies with active current
Ohmic Load Unit Reoload 310
REO Three-Phase Resistive Load Description Optional liquid cooling of our test devices allows for a compact design with reduced weight and a high protection class. With liquid-cooled resistive load units from REO, the energy dissipated in the water can be sustainably integrated into the heat process of the company and thus contribute positively to the overall energy efficiency of the company. The units cooled in this way generate less waste heat overall – this is a great advantage, especially in smaller halls or at high ambient temperatures. Advantages four three-phase fixed stages for testing auxiliary converters with active power Switching individual stages on and off under load using illuminated pushbuttons Display of voltages, currents, and direction of rotation Input Chokes for attenuating voltage spikes Outputs for current and voltage measurement Connections on terminals located inside the control cabinet TECHNICAL DATA* Nominal Voltage 3 x 440 V L/L or 3 x 254 V L/L 50/60Hz Currents 3 x 8 A 3 x 15.7 A 3 x 31.5 A 3 x 63 A Power 6 kW 12 kW 24 kW 48 kW Total Power 90 kW Frequency 50/60 Hz Protection class IP 20 *Of course, other voltages and power ratings can also be offered after consultation.
REOLOAD 310 Resistive Load Unit

Optional liquid cooling for our test equipment enables a compact design with lower weight and a high protection class.