Test Choke RPD 9039

Three-phase load reactor Description Drive inverters or output filters must be tested at nominal current, a process typically performed using motor-generator sets. Due to the high costs, test specimens can alternatively be loaded with Chokes that offer sufficient linearity and do not exceed the temperature limit at higher frequencies. Advantages small dimensions Cost-effective solution Technical data Cooling: AN Insulation class F Climatic category: 25/085/21 DIN IEC 68 Part 1 Max. winding temperature: 140 °C Protection rating: IP 00 Rated voltage : 400 V Rated current : 0,6 – 75 A Inductance : 3,15 – 254 mH Type Rated voltage [V] Rated current [A] Inductance [mH] DC-Resistance [mΩ] Power loss [W] RPD 9039/0,6 3 x 400 0,6 254 6009,2 20 RPD 9039/7,0 3 x 400 7 31,4 221,7 70 RPD 9039/32,0 3 x 400 32 8,550 34,3 230 RPD 9039/75,0 3 x 400 75 3,150 12,6 430 Dimensions in MM Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] øD1 [mm] A1 [mm] Copper [kg] Weight [kg] RPD 9039/0,6 125 91 85 100 52 5 x 8 9 33,1 1 2 RPD 9039/7,0 190 123 157 170 79 8 x 12 9 34,5 3 10 RPD 9039/32,0 300 168 264 224 120 10 x 18 9 34,7 11 38 RPD 9039/75,0 360 182 313 264 142 10 x 18 9 35,7 18 58
Test reactor NPT 8929

Single-phase test reactor Description These chokes are used in test laboratories as load chokes. They can be interconnected (almost) arbitrarily. If these chokes are used with appropriate resistors, testing under various cos(phi) is possible. This is required, for example, to test the connection and switching behavior of components Advantages Robust design High flexibility compact design Low losses Technical data Insulation class: F at 40° C Climatic category: 25/085/21 DIN IEC 68 Part 1 Max. winding temperature: 125° C Protection class: IP00 Nominal Voltage: 230 V Rated current: 0,5 – 32,5 A Inductance: 0,127 – 3180 mH Type Rated voltage [V] Rated current [A] Inductance [mH] DC-Resistance [mΩ] Power loss [W] NPT 8929 / 0,5 230 0,5 3180 55670,2 23 NPT 8929 / 1,25 230 1,25 1270 16880,0 43 NPT 8929 / 1,66 230 1,66 955 9977, 8 47 NPT 8929 / 2,5 230 2,5 636 6388,5 66 NPT 8929 / 5 230 5,0 318 1782,5 94 NPT 8929 / 32,5 230 32,5 0,318 0,0 39 NPT 8929 / 32,5 230 32,5 0,127 7,0 13 NPT 8929 / 32,5 230 32,5 0,318 0,0 27 Dimensions in MM Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] Connection [mm²] Copper [kg] Weight [kg] NPT 8929 / 0,5 120 96 205 76 77 7 x 13 2,5 0,7 5 NPT 8929 / 1,25 160 105 265 100 81 7 x 13 2,5 2 9,8 NPT 8929 / 1,66 160 115 270 100 91 7 x 13 2,5 3,1 12,2 NPT 8929 / 2,5 200 122 310 124 94 10 x 18 4 3,9 17 NPT 8929 / 5 240 153 355 144 125 10 x 18 4 7,3 29 NPT 8929 / 32,5 120 96 208 76 77 7 x 13 16 0,84 6,5 NPT 8929 / 32,5 100 82 190 63 65 6 x 10 16 0,44 3,6 NPT 8929 / 32,5 120 96 208 76 77 7 x 13 16 0,94 6,5
Test Reactor NPT 8919

Single-phase iron core reactor Description These chokes are used as load chokes in testing laboratories. They can be interconnected (almost) arbitrarily. If these chokes are used with appropriate resistors, testing is possible under various cos(phi). This is required, for example, to test the connection and switch-on behavior of components. Advantages Robust design High flexibility compact design Low losses Technical data Insulation class: F at 40° C Climatic category: 25/085/21 DIN IEC 68 Part 1 Max. winding temperature: 125° C Protection class: IP00 Nominal voltage: 230 – 600 V Nominal current: 1.5 – 32.5 A Inductance: 0.031 – 71 mH Optional extras Also available as IP 54 with: Input cable/output cable Input cable/output socket Complete cable connection solution for mains, output and control connections
Harmonic Filter CNW 999

Compensation choke (7 or 14% detuning factor) Description Detuning (p) of reactive current and harmonic compensation systems; protection of the capacitors Advantages small inductance tolerance Low-noise linear behavior even with currents greater than the rated current optional connection via terminals or cable Technical data According to: DIN EN 61558-2-20 Test voltage: L-L 2100 V, DC 1 min L-PE 2700 V, DC 1 min Overload: 1,5 x INenn 1 min / h Climate category: DIN IEC 60068-1 Thermal class: H Protection class: IP00 Output voltage: 25 – 600 V Output current: 2 – 600 A Output power: 1000 – 15000 W Input voltage switchable: Input voltage switchable [V] V Type detuning factor 7% Reactive power capacitors [kVAr] Resonance frequency [Hz] Detuning factor (p) [%] Rated current [A] Current @ 50Hz [A] Inductance per strand [mH] Copper [kg] Weight [kg] CNW 999/10/6 6,25 189 7 10,6 10,0 6,0 3 8 CNW 999/19/3 12,5 189 7 20,5 19,0 3,0 4 9 CNW 999/38/1,53 25 189 7 41,0 38,0 1,53 1 17 CNW 999/75/0,78 50 189 7 80,0 75,0 0,78 1 28 Type detuning factor 14% Reactive power capacitors [kVAr] Resonance frequency [Hz] Detuning factor (p) [%] Rated current [A] Current @ 50Hz [A] Inductance per strand [mH] Copper [kg] Weight [kg] CNW 999/9/14,5 6,25 134 14 9,1 9,0 14,5 5 9 CNW 999/19/6,9 12,5 134 14 19,1 19,0 6,9 5 15 CNW 999/38/3,5 25 134 14 38,2 38,0 3,5 1 24 CNW 999/76/1,73 50 134 14 76,5 76,0 1,73 1 43 Dimensions in mm Type detuning factor 7% L [mm] B [mm] H [mm] N1 [mm] N2 [mm] D1 [mm] D2 [mm] Distance [mm] Weight [kg] CNW 999/10/6 190 101 155 170 69 8×12 – 30 7 CNW 999/19/3 190 111 155 170 79 8×12 – 30 8 CNW 999/38/1,53 240 150 205 185 97 10×18 9 55 17 CNW 999/75/0,78 265 172 225 200 122 10×18 9 55 28 Type detuning factor 14% L [mm] B [mm] H [mm] N1 [mm] N2 [mm] D1 [mm] D2 [mm] Distance [mm] Weight [kg] CNW 999/9/14,5 190 97 157 170 69 8×12 – 30 9 CNW 999/19/6,9 240 111 209 185 88 8×12 – 45 15 CNW 999/38/3,5 265 265 225 200 104 10×18 9 55 24 CNW 999/76/1,73 300 197 225 224 144 10×18 9 65 43
Sine wave filter CNW M 933

Three-phase sine wave filter DESCRIPTION Sinusoidal input current – save costs and trouble-free operation. The line reactors in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66. For particularly long cable distances of > 100m between the frequency inverter and motor, the shielded cable used for EMC suppression can cause capacitive coupling. The sine wave filter is a low pass from inductance and capacitance and has a very low resonance frequency. So it is able to generate a largely sinusoidal current. The operation and the loss balance of the asynchronous motor behave like the normal mains operation. The typical motor noise with converter do not occur and a shielded cable to the motor can be dispensed. Losses and heating are greatly minimized and the leakage current will be reduced. Longer motor cable lengths are possible. The motor insulation is protected, thus increasing the service life. ADVANTAGES Usable in rough environment Optimal mechanical protection of the reactor Protection class up to IP 66 Assembly of different options: cables, terminals, terminal box Custom mounting plate for attachment possible Lower surface temperature – Output voltage is sinusoidal Switching edges are completely flattened High attenuation of spurious emissionsof lines Effective against symmetrical interference Motor cables possible to 1000m Saving the shielded cable possible Extended service life of electrical consumers Reduction of engine noise Low leakage currents on the motor Easy construction Production possible according to UL insulation system E251513 TYPICAL APPLICATIONS Drive systems for motor drives,Mechanical engineering,Elevators/ escalators,Pipes,Conveyor technology,Ventilation and air conditioning,Robotics,Automation technology,Power supplies,Wind turbines TECHNICAL SPECIFICATION Type Rated voltage [V] Rated current [A] Inductance [mH] Capacitance [μF] Copper weight [kg] Weight [kg] [kg] Cables [mm2] CNW M 933 / 2 up to 3 × 500 2 29,3 0,22 0,9 2,9 1,5 CNW M 933 / 4 4 14,6 0,33 0,9 2,9 1,5 CNW M 933 / 6 6 9,7 0,73 1.0 3,6 1,5 CNW M 933 / 8 8 5,3 0,73 1.0 3,6 1,5 CNW M 933 / 10 10 5,0 0,73 1,8 5,8 1,5 CNW M 933 / 12 12 4,9 1,1 2,3 7,5 1,5 CNW M 933 / 16 16 3,6 1,1 3,2 9,0 2,5 CNW M 933 / 20 20 2,9 1,5 3,6 13,0 4,0 CNW M 933 / 24 24 2,4 2,2 3,6 13,0 4,0 CNW M 933 / 30 30 2,0 2,2 10,0 28,0 6,0 CNW M 933 / 37 37 1,9 3,3 11,0 29,0 6,0 DIMENSIONS IN MM Type L1 (mm) B1 (mm) H1 (mm) Bolting Clamp Protection class L2 (mm) L3 (mm) B2 (mm) H2 (mm) N1 (mm) N2 (mm) ØD (mm) CNW M 933/2 185 80 57 M20 4mm² IP66 140 125 77 113 100 60 5,5 x 7,0 CNW M 933/4 185 80 57 M20 4mm² IP66 140 125 77 113 100 60 5,5 x 7,0 CNW M 933/6 185 80 57 M20 4mm² IP66 140 125 87 113 100 70 5,5 x 7,0 CNW M 933/8 185 80 57 M20 4mm² IP66 140 125 87 113 100 70 5,5 x 7,0 CNW M 933/10 200 80 80 M20 4mm² IP64* 175 155 99 137 130 79 5,5 x 12,0 CNW M 933/12 200 80 80 M20 4mm² IP64* 175 155 114 137 130 94 5,5 x 12,0 CNW M 933/16 200 120 100 M20 6mm² IP64* 195 200 125 165 165 100 9,0 x 13,0 CNW M 933/20 200 120 100 M25 6mm² IP64* 195 200 145 165 165 120 9,0 x 13,0 CNW M 933/24 200 120 100 M25 6mm² IP64* 195 200 145 165 165 120 9,0 x 13,0 CNW M 933/30 210 120 110 M32 16mm² IP64* 250 255 180 220 185 150 9,0 x 13,0 CNW M 933/37 210 120 110 M32 16mm² IP64* 250 255 180 220 185 150 9,0 x 13,0 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications
Sine wave filter CNW 961

Three-phase sine wave filter Plus++ DESCRIPTION The REO Sinus filter Plus++ enables to suppress interference not only on line cables to the motor but also to earth conductors.The REO Sinus filter Plus++ also feeds incurring bearing currents into the DC-link so that these may not cause any damage to the mechanics. REO Sinus filter Plus++ is used in any kind of application which requires safe mechanical continuous power and reliability. Examples of such applications are: Water treatment – especially heat pumps – and materials’ safety in general. TYPICAL APPLICATIONS Examples of such applications are: Water treatment – especially heat pumps – and materials’ safety in general.The REO Sinusfilter Plus++ also feeds incurring bearing currents into the DC-link so that these may not cause any damage to the mechanics. REO Sinusfilter Plus++ is used in any kind of application which requires safe mechanical continuous power and reliability. REO Sinusfilter Plus++ is used in any kind of application which requires safe mechanical continuous power and reliability. ADVANTAGES Total harmonic distortion U from < 5% Use of unshielded cables Low EMC influence of conductors laid in parallel Simple integral EMC filter in the inverter sufficient No need for external line filters Compact and low-noise construction Technical Data Conforming to: EN 61558-2-20 Test voltage: L-L 1000 V, DC 1 min; L-PE 2500 V, DC 1 min Rated voltage: U = 3 x 500 V Insulation material class: T40/B Climatic category: DIN IEC 60068-1 Overload: 1,5 x INenn 1 min / h TECHNICAL SPECIFICATION Type Rated voltage [V] Rated current [A] Inductance Total [mH] Capacitance [μF] Copper [kg] Weight [kg] [kg] CNW 961 / 2 up to 3 × 500 2 33,4 0,11 1,4 5,2 CNW 961 / 4 4 16,7 0,34 1,7 5,5 CNW 961 / 6 6 11,0 0,50 3,0 5,8 CNW 961 / 10 10 6,60 1,10 4,5 9,1 CNW 961 / 16 16 4,20 1,10 5,0 13,0 CNW 961 / 24 24 2,83 1,50 6,5 17,3 CNW 961 / 30 30 2,20 2,20 12,0 37,0 CNW 961 / 37 37 1,64 2,20 12,5 38,0 CNW 961 / 48 48 1,41 3,30 16,2 42,0 CNW 961 / 60 60 0,91 4,70 17,0 62,0 DIMENSIONS IN MM
Sinusoidal Filter CNW 931

Single-phase sine wave filter 6,15% Uk DESCRIPTION Smoothing of the current and voltage in order to realize long connecting paths. ADVANTAGES Low-temperature rise Low-noise Manufacturing according to UL Insulation SystemE 251513 possible Easy installation Adaptation to motor cables up to 1000 meters possible Saving the shielded cable possible TYPICAL APPLICATIONS Drive systems for motor drives,Mechanical engineering,Elevators/ escalators,Pipes,Conveyor technology,Ventilation and air conditioning,Robotics,Automation technology,Power supplies,Wind turbines Technical Data Ambient temperature: 50 ° C Protection rating: IP00 Insulation class: F Linearity: LN at 1.2 x IN u. ≥ 0.8 x LN at 1.5 x IN Test voltage: 3 kV Rated voltage: 230 V Uk: 6.15 % Overvoltage category: 2 Pollution degree: 2 Cooling: ON Switching frequency: ≥ 4 kHz Current ripple: ≤ 20% at 4 kHz TECHNICAL SPECIFICATION Type Nominal current [A] Inductance [mH] Resistance R20 [mΩ] Capacitance [µF] Power dissipation [W] Uk @ 230 V Uk @ 133 V Uk @ 400 V Copper [kg] CNW 931 / 3 3 15 349,5 6,8 17 6,2 % 10,6 % 3,5 % 0,15 CNW 931 / 4 4 11,3 275,2 10 22 6,2 % 10,7 % 3,6 % 0,23 CNW 931 / 6 6 7,5 133,1 10 29 6,2 % 10,6 % 3,5 % 0,29 CNW 931 / 8 8 5,6 94,4 20 33 6,1 % 10,6 % 3,5 % 0,33 CNW 931 / 10 10 4,5 62,2 20 37 6,2 % 10,6 % 3,5 % 0,53 CNW 931 / 12 12 3,75 59,9 20 43 6,2 % 10,6 % 3,5 % 0,64 CNW 931 / 16 16 2,8 43,4 20 56 6,1 % 10,6 % 3,5 % 0,82 Dimensions in mm Type L [mm] B1 [mm] B2 [mm] H [mm] N1 [mm] N2 [mm] Clamp [mm²] Weight [kg] CNW 931 / 3 64 72 59 115 44 47 1,5 mm² 0,9 CNW 931 / 4 66 74 64 130 50 49 1,5 mm² 1,1 CNW 931 / 6 83 80 69 153 56 56 1,5 mm² 1,8 CNW 931 / 8 83 80 69 153 56 56 2,5 mm² 1,9 CNW 931 / 10 84 90 84 160 71 71 2,5 mm² 2,5 CNW 931 / 12 96 86 86 170 80 71 2,5 mm² 3 CNW 931 / 16 96 110 110 170 80 95 2,5 mm² 4,4 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Certifications
Sine wave filter N CNW 933

Three-phase sine wave filter DESCRIPTION NEW SERIES! The new series not only scores points for its faster delivery time, but also for its resource conservation and increased efficiency. Sinusoidal output voltage – Save costs and ensure trouble-free operation. For particularly long cable distances of > 100m between the frequency inverter and motor, the shielded cable used for EMC suppression can cause capacitive coupling. In such cases, a conventional motor choke cannot provide sufficient damping. The sine filter is a low-pass filter consisting of inductance and capacitance, thus having a very low resonance frequency. As a result, it is able to generate a largely sinusoidal current. The operation and loss balance of the asynchronous motor behave as they would during normal mains operation. The typical motor noises during inverter operation do not occur, and depending on the system, shielded cables to the motor can be omitted. Losses and heating are greatly minimized, and the leakage current is reduced. Longer motor cable lengths can be used. The motor insulation is protected, thereby increasing its lifespan. The sine filter also effectively dampens conducted interference in the lower frequency range. Losses and typical noises in the motor laminations are reduced. ADVANTAGES – Output voltage is sinusoidal Switching edges are completely flattened High attenuation of spurious emissionsof lines Effective against symmetrical interference Motor cables possible to 1000m Saving the shielded cable possible Extended service life of electrical consumers Reduction of engine noise Low leakage currents on the motor Easy construction Production possible according to UL insulation system E251513 TYPICAL APPLICATIONS Drive systems for motor drives,Mechanical engineering,Elevators/ escalators,Pipes,Conveyor technology,Ventilation and air conditioning,Robotics,Automation technology,Power supplies,Wind turbines Technical Data Rated voltage: U ≤ 3 x 500 V Max. voltage ripple: 5% Field frequency: 0 – 60 Hz Drive Switching frequency of the inverter: up to 150 A >4kHz, from 150 A >1.5kHz Short-circuit voltage Uk: 8% (at 400V) Voltage drop: 18,4 V/Strang (at IN and 50Hz) Max. Cable length to the motor: 600 m (unshielded) 1000m (shielded) According to: EN 60289 / EN 61558 Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s Insulation class: T40/F Protection rating: IP00 Climatic category: DIN IEC 60068-1 Overload: 1,5 x INenn 1 min / h Ambient temperature: 40 °C Design: standing on foot angle TECHNICAL SPECIFICATION Type Nominal voltage U [V] Nominal current I [A] Inductance L [mH] CapacitanceC [µF] LossesP [W] Mass[kg][kg] WeightCu [kg] Weight Al [kg] N CNW 933 / 2 50050 / 60 Hz 2 25 0,1 37 1,15 0,5 – N CNW 933 / 4 4 12,5 0,33 30 2,4 0,9 – N CNW 933 / 6 6 7,5 0,33 40 2,9 0,8 – N CNW 933 / 8 8 5,8 0,73 65 3,0 1,0 – N CNW 933 / 10 10 5,6 1,1 50 4,6 1,9 – N CNW 933 / 12 12 4,7 1,5 60 6,3 2,3 – N CNW 933 / 16 16 3,4 1,5 167 7,8 3,4 – N CNW 933 / 20 20 2,9 1,5 212 9,3 3,3 – N CNW 933 / 24 24 2,4 2,2 85 11,0 3,6 – N CNW 933 / 30 30 1,9 2,2 240 16,0 7,4 – N CNW 933 / 37 37 1,6 3,3 160 22,5 8,0 – N CNW 933 / 48 48 1,2 4,7 190 22,0 8,0 – N CNW 933 / 60 60 0,95 6,8 230 27,0 10,0 – N CNW 933 / 75 75 0,79 6,8 225 34,0 13,8 – N CNW 933 / 90 90 0,68 8,0 317 40,0 12,6 – N CNW 933 / 115 115 0,51 12,0 320 60,0 25,6 – N CNW 933 / 120 120 0,5 18,o 340 58,0 0,9 6,6 N CNW 933 / 150 150 0,326 40,0 310 61,0 1,1 7,1 N CNW 933 / 180 180 0,325 40,0 390 76,0 1,1 8,0 N CNW 933 / 200 200 0,293 47,0 550 79,0 1,5 6,0 N CNW 933 / 250 250 0,236 68,0 620 89,0 1,5 6,9 N CNW 933 / 350 350 0,167 68,0 810 104,0 3,2 11,3 N CNW 933 / 400 400 0,146 120 980 106,0 3,2 11,3 N CNW 933 / 450 450 0,130 120 1210 181,0 3,2 14,8 N CNW 933 / 500 500 0,118 120 1420 208,0 3,8 15,3 N CNW 933 / 600 600 0,098 180 1590 227,0 7,1 17,6 N CNW 933 / 700 700 0,085 180 1570 258,0 7,1 30,1 N CNW 933 / 750 750 0,078 220 1750 259,0 7,1 30,1 N CNW 933 / 800 800 0,074 220 1910 297,0 6,7 28,8 N CNW 933 / 900 900 0,065 240 2360 315,0 14,2 29,4 N CNW 933 / 1000 1000 0,059 240 2610 370,0 14,2 28,4 N CNW 933 / 1200 1200 0,05 360 2980 417,0 14,2 33,4 Dimensions in mm Type Length L1 [mm] Length L2 [mm] Width B1 [mm] Width B2 [mm] High max. H1 [mm] Mounting N1 [mm] Mounting N2 [mm] Mounting D1 [mm x mm] Clamps / Cross section [mm²] Angle [mm x mm] Connection A1 [mm] Connection D2 [mm] PE Ø [mm] N CNW 933 / 2 80 96 45 56,5 110 56 34 5 x 8 1,5 – – – Flat connector 6.3×0.8 N CNW 933 / 4 125 – 61 – 167 100 43 5 x 8 2,5 – – – 2,5 N CNW 933 / 6 125 – 72 – 175 100 56 5 x 8 2,5 – – – 2,5 N CNW 933 / 8 125 – 72 – 175 100 56 5 x 8 2,5 – – – 2,5 N CNW 933 / 10 155 – 77 – 205 130 57 8 x 12 10 – – – 10 N CNW 933 / 12 155 – 92 – 205 130 72 8 x 12 10 – – – 10 N CNW 933 / 16 190 – 82 – 235 170 58 8 x 12 10 – – – 10 N CNW 933 / 20 190 – 125 – 215 170 68 8 x 12 10 – – – 10
Line reactor N CNW 905

Line reactor N CNW 905 Three-phase line reactor 2% Uk DESCRIPTION NEW SERIES! The new series not only scores points for its faster delivery time, but also for its resource conservation and increased efficiency. Power Noise Reduction – save up to 15% energy costs. A line reactor relieves the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a line reactor the inverter electronics and DC-capacitors will be protected. Starting currents and current peaks are reduced up to 30%. Line reactors help to comply with international power quality standards IEEE 519 or EN 61000-3-2. ADVANTAGES Compact design Extended service life of electrical consumers Low-temperature rise Attenuation of current spikes up to 30% Reduction of input current up to 15% Low-noise Production possible according to UL insulation system E251513 Typical applications Drive systems for motor drives: Mechanical engineering, Elevators / escalators, Pipes, Conveyor technology, Ventilation and air conditioning, Robotics, Automation technology, Power supplies and Wind turbines Technical Data Rated voltage: U ≤ 3 x 500 V Short circuit: Uk 2% (400VAC/50Hz, INenn) Frequency: 50/60 Hz According to: EN 60289 / EN 61558 Test voltage: LL 2500 V, DC 1min; L-PE 2500 V, DC 1min Insulation class: T40/F Protection rating: IP00 Climatic category: DIN IEC 60068-1 Overload: 1,5 x INenn 1 min / h Design: standing on foot angle TECHNICAL SPECIFICATION Type Nominal voltage / nominal frequency UN [V] Nominal current IN [A] Inductance L [mH] Losses P [W Weight [kg Weight Cu [kg] Weight Al [kg] N CNW 903 /3 500 50 / 60 Hz 3 9,800 16 1.0 0.2 – N CNW 903 /6 500 50 / 60 Hz 6 4,880 25 2.0 0.3 – N CNW 903 /8 500 50 / 60 Hz 8 3,680 35 2.0 0.3 – N CNW 903 /10 500 50 / 60 Hz 10 2,930 36 3.0 0.4 – N CNW 903 /12 500 50 / 60 Hz 12 2,450 38 3.0 0.45 – N CNW 903 /16 500 50 / 60 Hz 16 1,830 48 4.0 0.7 – N CNW 903 /25 500 50 / 60 Hz 25 1,170 63 5.2 0.8 – N CNW 903 /36 500 50 / 60 Hz 36 0,810 67 7.0 1.9 – N CNW 903 /50 500 50 / 60 Hz 50 0,590 112 9.0 1.2 – N CNW 903 /70 500 50 / 60 Hz 70 0,420 180 11 2.1 – N CNW 903 /90 500 50 / 60 Hz 90 0,330 144 17 2.5 – N CNW 903 /110 500 50 / 60 Hz 110 0,270 179 18 1.8 – N CNW 903 /125 500 50 / 60 Hz 125 0,235 220 17 2.6 – N CNW 903 /160 500 50 / 60 Hz 160 0,180 145 22 5.0 – N CNW 903 /200 500 50 / 60 Hz 200 0,147 187 26 1.3 3.8 N CNW 903 /250 500 50 / 60 Hz 250 0,118 254 35 1.3 3.0 N CNW 903 /300 500 50 / 60 Hz 300 0,098 250 37 1.3 4.7 N CNW 903 /350 500 50 / 60 Hz 350 0,084 267 45 2.6 5.0 N CNW 903 /400 500 50 / 60 Hz 400 0,074 365 52 2.6 5.2 N CNW 903 /500 500 50 / 60 Hz 500 0,059 423 58 2.9 7.8 N CNW 903 /600 500 50 / 60 Hz 600 0,049 450 71 5.0 6.9 N CNW 903 /700 500 50 / 60 Hz 700 0,042 493 88 5.0 9.2 N CNW 903 /800 500 50 / 60 Hz 800 0,037 545 96 5.1 8.3 N CNW 903 /900 500 50 / 60 Hz 900 0,033 655 108 12.5 10.1 N CNW 903 /1000 500 50 / 60 Hz 1000 0,029 775 108 12.5 10.1 N CNW 903 /1200 500 50 / 60 Hz 1200 0,024 1009 133 13.9 12.4 DIMENSIONS IN MM Type Lenght L1 (mm) Lenght L2 (mm) Broad B1 (mm) Broad B2 (mm) High max. H1 (mm) Mounting N1 (mm) Attachment N2 (mm) Attachment D1 (mm x mm) Clamp/ Cable Lug [mm²] Angle [mm x mm] Connection A1 (mm) Connetion D2 (mm) PE N CNW 903 /3 65 78 50 60 95 50 38 5 x 8 2.5 M4 N CNW 903 /6 80 96 55 65 110 56 43 5 x 8 2.5 M4 N CNW 903 /8 125 120 61 66 130 100 45 5 x 8 2.5 M4 N CNW 903 /10 125 120 71 76 130 100 55 5 x 8 2.5 M4 N CNW 905 /12 125 120 71 76 130 100 55 5 x 8 2.5 M4 N CNW 903 /16 155 150 76 76 155 130 54 8 x 12 2.5 M4 N CNW 903 /25 155 150 91 101 170 130 69 8 x 12 10 M4 N CNW 903/36 190 180 81 91 195 170 57 8 x 12 10 M6 N CNW 903 /50 190 180 101 111 195 170 77 8 x 12 10 M6 N CNW 903 /70 230 136 200 176 73 9 x 13 16 (M8) 45 M8 N CNW 903 /90 230 150 200 176 95 9 x 13 16 (M8) 45 M8 N CNW 905 /110 240 150 210 185 97 10 x 18 16 (M8) 45 M8 N CNW 905 /125 240 150 210 185 95 10 x 18 45 M8 N CNW 903 /160 240 175 210 185 103 10 x 18 35 (M10) 55 M8 N CNW 903 /200 300 148 270 224 95 10 x 18 30 x 4 39 11 M12 N CNW 903 /250 300 184 270 224 125 10 x 18 30 x 4 39 11 M12 N CNW 903 /300 300 190 270 224 125 10 x 18 30 x 4 39 11 M12 N CNW 903 /350 340 192 305 248 130 10 x 18 40 x 5 49 13 M12 N CNW 903 /400 360 195 315 264 142 10 x 18 40 x 5 49