Voltage Constant REOSTAB DNK
Three-phase voltage stabilizers for stationary operation with common or separate control of the three phases (size SD 1 to SD 20).
Inductive Load Unit REOCHOKE 300
The three-phase choke load consists of three iron core chokes, each with three taps, and is used for testing converters and switching power supplies.
Inductive Load Unit REOCHOKE 300/69
Infinitely adjustable three-phase choke load consisting of a three-phase variable autotransformer and a three-phase iron core choke connected on the secondary side, for testing converters and power supplies with reactive current.
REOLOAD 302 Ohmic Load Units
Eight three-phase fixed levels for testing power supplies and thermal behavior with active power.
Ohmic load unit REOLOAD 301
Ten fixed levels per plug-in unit for testing contacts, converters and switched-mode power supplies with active current
REOLOAD 310 Resistive Load Unit
Optional liquid cooling for our test equipment enables a compact design with lower weight and a high protection class.
REOLOAD 300 Ohmic Load Unit
Example of a customer-specific resistor load unit consisting of 15 resistor groups (liquid-cooled) and 4 variable resistors with AC motor drive.
REOLAB 340, 350
The three-phase power supplies with economy winding regulate the output voltage with an accuracy of approx. 1.5 % of the final value.
Adjustable and constant power supply REOLAB 330, 370
Three-phase-voltage supplies with separate windings, motor drive and electronic voltage control with safety circuits and warning beacons are suitable for the endurance testing of cable terminations. The regulation precision of the output voltage is approx. 1.5%.
Adjustable & Constant Voltage Supply Reolab 320
Three-phase-voltage supplies with separate windings, motor drive and electronic voltage control Description Three-phase-voltage supplies with separate windings, motor drive and electronic voltage control with safety circuits and warning beacons are suitable for the endurance testing of cable terminations. The regulation precision of the output voltage is approx. 1.5%. In conjunction with the REOLAB 220 as a heavy current source for temperature rise testing, the REOLAB 320 can be used for insulation tests on cables and cable terminations. Advantages No harmonics waves No EMC interference Clean sinusoidal form TECHNICAL DATA* Input voltage 3 x 400 V L/L or 3 x 230 V L/N Output voltage 3 x 0 – 3000 VAC, 3 x 0 – 4000 VAC, 3 x 0 – 5000 VAC Output current 3 x 0,25 AAC Output power 1,3 – 2,16 kVA Schaltgruppe Stern / Stern Protection Class IP 20 in mobile housing Frequency range 50/60 Hz *Of course, other voltages and power ratings can also be offered after consultation. In addition, different operating options/operating concepts and industrial interfaces are possible. Datasheet All data and configurations can be found in our product datasheet. Download Datasheet